OS GSO ISO/ASTM 51608:2015
ISO/ASTM 51608:2015
Omani Standard
Current Edition
·
Approved on
03 September 2015
Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing at energies between 50 keV and 7.5 MeV
OS GSO ISO/ASTM 51608:2015 Files
English
16 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO ISO/ASTM 51608:2015 Scope
1.1 This practice outlines the dosimetric procedures to be followed during installation qualification, operational qualification, performance qualification and routine processing at an X-ray (bremsstrahlung) irradiator. Other procedures related to operational qualification, performance qualification and routine processing that may influence absorbed dose in the product are also discussed.
NOTE 1: Dosimetry is only one component of a total quality assurance program for adherence to good manufacturing practices used in radiation processing applications.
NOTE 2: ISO/ASTM Practices 51649, 51818 and 51702 describe dosimetric procedures for electron beam and gamma facilities for radiation processing.
1.2 For radiation sterilization of health care products, see ISO 11137-1, Sterilization of health care products – Radiation – Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices. In those areas covered by ISO 11137-1, that standard takes precedence.
1.3 For irradiation of food, see ISO 14470, Food irradiation – Requirements for development, validation and routine control of the process of irradiation using ionizing radiation for the treatment of food. In those areas covered by ISO 14470, that standard takes precedence.
1.4 This document is one of a set of standards that provides recommendations for properly implementing and utilizing dosimetry in radiation processing. It is intended to be read in conjunction with ISO/ASTM Practice 52628, “Practice for Dosimetry in Radiation Processing”.
1.5 In contrast to monoenergetic gamma radiation, the X-ray energy spectrum extends from low values (about 35 keV) up to the maximum energy of the electrons incident on the X-ray target (see Section 5 and Annex A1).
1.6 Information about effective or regulatory dose limits and energy limits for X-ray applications is not within the scope of this practice.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Best Sellers From Food and Agriculture Sector
GSO 150-2:2013
Gulf Standard
Expiration dates for food products - Part 2 :
Voluntary expiration dates
OS GSO 150-2:2013
GSO 150-2:2013
Omani Standard
Expiration dates for food products - Part 2 :
Voluntary expiration dates
OS GSO 9:2022
GSO 9:2022
Omani Standard
Labeling of prepackaged food stuffs
GSO 9:2022
Gulf Technical Regulation
Labeling of prepackaged food stuffs
Recently Published from Food and Agriculture Sector
GSO 2850:2026
Gulf Standard
Complete chicken feed
GSO ISO 22002-6:2026
ISO 22002-6:2025
Gulf Standard
Prerequisite programmes on food safety — Part 6: Feed and animal food production
GSO EN 17504:2026
EN 17504:2022
Gulf Standard
Animal feeding stuffs: Methods of sampling and analysis - Determination of gossypol in cotton seed and feeding stuff by LC-MS/MS
GSO 2849:2026
Gulf Standard
Compound Feed for Livestock